Land at Whitings Lane, Burn (timber storage shed)

appeal 6007535·North Yorkshire·28 August 2026dismissed
Decision
dismissed, 28 August 2026
Decided by
Planning Inspector: N Teasdale
Authority
North Yorkshire (Yorkshire and the Humber)
Appeal reference
6007535
Application reference
ZG2025/0803/FUL
Procedure
written representations
Development
Demolition of a single-storey warehouse and erection of a 32 m x 10 m steel portal-frame timber storage building (B8) for a business based elsewhere
Site context
open countryside, PDL, flood zone 2, flood zone 3
Green Belt
No
Framework applied
August 2026 NPPF
Determinative policies
F5, S5(1)(d), DP3
Development plan policies
Selby District Local Plan 2005 ENV1, EMP2, Selby Core Strategy 2013 SP2, SP13, SP15, SP18, SP19
Main issues
character and appearance; flood risk; location of employment development

Summary

Replacement of a small warehouse in open countryside near Burn with a much larger steel timber-storage shed, for a firm based in the East Riding. Dismissed. The site partly lies in Flood Zones 2 and 3, and the sequential test covered just one alternative site, itself in Flood Zone 3. The building would be industrial and prominent. As a new standalone storage use it did not support the local rural economy. S5(1)(d) PDL support was "substantially outweighed".

Issues and findings

Planning balance

The S5 balance was run briefly inside the location issue (DL ¶23). Flood, character and economic-location harms substantially outweighed very limited direct economic benefits. The final conclusion is plan-led under s38(6) (DL ¶28).

What made the difference

A thin sequential test. The appellant looked at one site, which was itself in Flood Zone 3, and ignored the Council's list of allocations and windfall sites. Add a building much larger than the one it replaced, and a user with no local business link, and the PDL status could not carry it. A district-wide search, a building close in size to the existing one, or an existing local operator expanding on site would have changed the picture.

Transferable points

Policy findings

Policy codes are those of the National Planning Policy Framework (August 2026) unless a development plan is named.

PolicyFindingWeightNote
F5failbrief FRA does not show the F5(2)(b) exception applies; sequential test looked at one Flood Zone 3 site only and ignored allocations, windfalls and commercial listings (DL 11-15)
F4failsite-specific FRA inadequate (DL 11, 13)
S5(1)(d)failPDL "offered support" but benefits substantially outweighed by adverse effects under the national decision-making policies; use does not need a rural location (DL 23)
DP3failsubstantially larger, industrial-looking building prominent from Burn Lane; cited as Framework "chapter 14" (DL 8-10)
E4failnew standalone B8 use for an off-site business, not expansion of an existing rural business; cited as Framework "chapter 7" (DL 21-22, 26)

Key facts

Sources

This note is one of the decisions behind the NPPF 2026 Navigator, which shows how each Framework test has been applied across all the decisions in the database. Also available as Markdown.