4A Gimmels Gate, Spalding

appeal 6009598·South Holland·18 September 2026dismissed
Decision
dismissed, 18 September 2026
Decided by
Planning Inspector: R Gee
Authority
South Holland (East Midlands)
Appeal reference
6009598
Application reference
H11-1294-25
Procedure
written representations
Development
Retrospective change of use of storage shed to residential
Homes
1
Site context
open countryside, flood zone 3
Green Belt
No
Framework applied
August 2026 NPPF
Determinative policies
S5(1)(c), S5(2), F6, F7
Development plan policies
South East Lincolnshire Local Plan 2011-2036 Policies 1, 2, 3, 4, 17, 23
Main issues
flood risk; location; living conditions

Summary

A retrospective conversion of a storage shed to a dwelling near Spalding. The location was acceptable under S5(1)(c), and the Local Plan's requirement that a converted building have architectural merit was held inconsistent with the new Framework. The appeal failed on flood risk: Flood Zone 3a with no workable design for the 400 mm floor raise. The F6/F7 failure engaged S5(2), so the benefits were "substantially outweighed".

Issues and findings

Planning balance

S5(1)(c) applied. Flood harm had substantial weight and the benefits limited weight (DL ¶29-30). The inspector quotes "Paragraph 2(c) of NDMP S5", in fact S5(2): where a "should be refused" policy is failed, the benefits are likely substantially outweighed (DL ¶31-32).

What made the difference

The flood evidence. The principle was won under S5(1)(c), and local policy was trimmed back to the Framework's test, but a conversion in FZ3a with an undesigned floor raise cannot show lifetime safety.

Transferable points

Policy findings

Policy codes are those of the National Planning Policy Framework (August 2026) unless a development plan is named.

PolicyFindingWeightNote
S5(1)(c)passbuilding of permanent and substantial construction; LP Policy 23 requirement for architectural/historic merit inconsistent with Framework, limited weight to conflict; no need to prove countryside necessity once (c) met (DL 12-14)
F5not-engagedsequential test not required for this change of use (DL 5)
F6failsubstantialFlood Zone 3a, "danger for some", breach depth up to 0.25 m; 400 mm floor raise undrawn and not shown achievable in existing low building - not left to condition (DL 5-10, 29)
F7failsafety for lifetime not demonstrated - "should be refused" policy (DL 10, 32)
S5(2)failF-policy failure engages S5(2) - benefits substantially outweighed (DL 31-33)

Key facts

Sources

This note is one of the decisions behind the NPPF 2026 Navigator, which shows how each Framework test has been applied across all the decisions in the database. Also available as Markdown.