- Decision
- dismissed, 18 September 2026
- Decided by
- Planning Inspector: R Gee
- Authority
- South Holland (East Midlands)
- Appeal reference
- 6009598
- Application reference
- H11-1294-25
- Procedure
- written representations
- Development
- Retrospective change of use of storage shed to residential
- Homes
- 1
- Site context
- open countryside, flood zone 3
- Green Belt
- No
- Framework applied
- August 2026 NPPF
- Determinative policies
- S5(1)(c), S5(2), F6, F7
- Development plan policies
- South East Lincolnshire Local Plan 2011-2036 Policies 1, 2, 3, 4, 17, 23
- Main issues
- flood risk; location; living conditions
Summary
A retrospective conversion of a storage shed to a dwelling near Spalding. The location was acceptable under S5(1)(c), and the Local Plan's requirement that a converted building have architectural merit was held inconsistent with the new Framework. The appeal failed on flood risk: Flood Zone 3a with no workable design for the 400 mm floor raise. The F6/F7 failure engaged S5(2), so the benefits were "substantially outweighed".
Issues and findings
- S5(1)(c): PASS, and local policy displaced. Policy 23's requirement "that the building is of architectural or historic merit … [is] not consistent with the revised Framework, which contains no equivalent requirement … The building is of permanent and substantial construction … the proposal accords with criterion c) of S5. I therefore afford only limited weight to the conflict with Policy 23" (DL ¶12).
- No need to prove necessity once a limb is met. "As the proposal would accord with criterion 1 c) of Policy S5, it is not necessary for it to satisfy each of the alternative criteria" (DL ¶13).
- Flood (F6/F7): FAIL. "no plans or drawings have been submitted that adequately demonstrate how/if the raising could be achieved" (DL ¶8). This could not be left to condition because it "is fundamental to ensuring the safe occupation" (DL ¶9).
- Transition. "The revised Framework introduced a presumption in favour of sustainable development for certain proposals outside of settlement boundaries through NDMPs S3 and S5" (DL ¶27).
Planning balance
S5(1)(c) applied. Flood harm had substantial weight and the benefits limited weight (DL ¶29-30). The inspector quotes "Paragraph 2(c) of NDMP S5", in fact S5(2): where a "should be refused" policy is failed, the benefits are likely substantially outweighed (DL ¶31-32).
What made the difference
The flood evidence. The principle was won under S5(1)(c), and local policy was trimmed back to the Framework's test, but a conversion in FZ3a with an undesigned floor raise cannot show lifetime safety.
Transferable points
- Local conversion policies that add an architectural-merit test are inconsistent with S5(1)(c) and carry limited weight (DL ¶12).
- Meeting one S5(1) limb is enough. Countryside necessity (S5(1)(b)) need not also be shown (DL ¶13).
- Flood-mitigation fundamentals (floor raising in an existing building) cannot be left to condition (DL ¶9).
- F6/F7 failure engages S5(2) and defeats an S5(1)(c) scheme (DL ¶31-33).
- The letter's "Paragraph 2(c) of NDMP S5" is a slip: S5(2) has no sub-paragraph (c); the words mirror S4(2)(c) (DL ¶31).
Policy findings
Policy codes are those of the National Planning Policy Framework (August 2026) unless a development plan is named.
| Policy | Finding | Weight | Note |
|---|---|---|---|
| S5(1)(c) | pass | building of permanent and substantial construction; LP Policy 23 requirement for architectural/historic merit inconsistent with Framework, limited weight to conflict; no need to prove countryside necessity once (c) met (DL 12-14) | |
| F5 | not-engaged | sequential test not required for this change of use (DL 5) | |
| F6 | fail | substantial | Flood Zone 3a, "danger for some", breach depth up to 0.25 m; 400 mm floor raise undrawn and not shown achievable in existing low building - not left to condition (DL 5-10, 29) |
| F7 | fail | safety for lifetime not demonstrated - "should be refused" policy (DL 10, 32) | |
| S5(2) | fail | F-policy failure engages S5(2) - benefits substantially outweighed (DL 31-33) |
Key facts
- Shed next to a cluster of houses and businesses at Gimmels Gate / Roman Bank - not isolated
- Flood Zone 3a; SFRA future hazard "danger for some"; breach depths up to 0.25 m to 2115
- 48 sq m studio (NDSS 50 sq m) found acceptable; headroom after floor raise unknown
Sources
This note is one of the decisions behind the NPPF 2026 Navigator, which shows how each Framework test has been applied across all the decisions in the database. Also available as Markdown.