11 Quantock Road, Weston-super-Mare

appeal 6007423·North Somerset·22 September 2026dismissed
Decision
dismissed, 22 September 2026
Decided by
Planning Inspector: S Harrington
Authority
North Somerset (South West)
Appeal reference
6007423
Application reference
26/P/0180/FUL
Procedure
written representations
Development
Single-storey dwelling in rear garden of flats, with demolition of garage and alterations to existing flats
Homes
1
Site context
inside settlement, flood zone 3, garden land
Green Belt
No
Framework applied
August 2026 NPPF
Determinative policies
F5, F6, S4
Development plan policies
North Somerset Core Strategy 2017 CS3, CS12, Sites and Policies Plan Part 1 2016 DM1, DM32, DM37, DM38, Residential Design Guide SPD 2013
Main issues
flood risk sequential and exception tests; neighbour living conditions; future occupier living conditions

Summary

One bungalow in a rear garden in Weston-super-Mare, in Flood Zone 3a on the SFRA. Dismissed. The sequential test was flawed: it discounted sites for being for sale or larger than needed. The exception test also failed, because a single-storey dwelling had no refuge and no safe access or egress. HO7 was given substantial weight (no 5YHLS), but F5/F6 were treated as refusal policies and outweighed it. Living conditions were acceptable.

Issues and findings

Planning balance

S4 framed (DL ¶25). For: HO7 substantial weight for one dwelling given no 5YHLS, plus modest economic and social benefits (DL ¶26). Against: "Framework Policy F6 indicates that the proposal would not be appropriate and should be refused, to which I afford significant weight. Consequently, I find that the proposal would not result in sustainable development" (DL ¶27). The letter never states that benefits were substantially outweighed, and weighs the flood harm at only "significant" against a "substantial" HO7 benefit. The logic rests on F6 as a refusal trigger (implicitly S4(2)).

What made the difference

A defective sequential test and no evidence of safe refuge or escape. Contrast PINS-6004929 (Catford), where a missing sequential test was outweighed because the scheme reduced risk by removing basement bedrooms and much of the surrounding area floods. Here a new single-storey dwelling increased the number of people exposed, with no refuge. A two-storey design with refuge and a properly reasoned sequential test (not discounting sites on ownership or size) would have given the appellant a much stronger case.

Transferable points

Policy findings

Policy codes are those of the National Planning Policy Framework (August 2026) unless a development plan is named.

PolicyFindingWeightNote
F5failsignificantSFRA FZ3a governs under F5(3) despite appellant's own levels survey; sequential test wrongly discounted sites on ownership/sale status and larger size (DL 4-12)
F6failsignificantexception test not met; single storey with no refuge, no safe access/egress detail, no wider sustainability benefits; F6 indicates refusal (DL 13, 27)
HO7benefitsubstantialno 5YHLS; one dwelling given substantial weight (DL 26)
S4failnot expressly concluded as substantially outweighed; "would not result in sustainable development" (DL 25-27)
DP3passneighbour and future-occupier living conditions acceptable though cramped (DL 15-21)